亚洲天天-亚洲天堂中文字幕-亚洲天堂中文网-亚洲天堂中文-亚洲天堂在线播放-亚洲天堂影院在线观看

Unipulse F701 basic weighing controller

Unipulse F701 basic weighing controllerF701 is a general-purpose weighing controller that is compatible with all weighing systems. This is a practical device excellent in cost effectiveness, which is

  • Brand:: Unipulse
  • Model:: F701

Unipulse F701 basic weighing controller

F701 is a general-purpose weighing controller that is compatible with all weighing systems. This is a practical device excellent in cost effectiveness, which is equipped with the final discharge function allowing high-accuracy feeding and discharging weighing control, the weighing sequence function essential to hopper and packing scales, and the interface connectable to various peripherals such as RS-232C and BCD output.

F701-1.jpg

ANALOG SECTION
Excitation voltage10V DC ±5%, Output current; within 120mA, remote sense type (Up to 4 loadcells at 350Ω are parallel-connectable.)
Zero adjustment range0 - 1.5mV/V for HI gain
0 - 3.0mV/V for LO gain (digital adjustment) 
Input of approx. 0.5mV/V or 1.0mV/V, Selectable adjust to zero [by dip switch on the rear panel]
Gain adjustment range2 stages of gain selectable according to the output of loadcell [by dip switch on the rear panel]
0.5 - 1.5mV/V for HI gain, 1.0 - 3.0mV/V for LO gain (digital adjustment)
Min. input sensitivity0.5μV / count
AccuracyNon-linearity: within 0.01%/FS
Zero drift: within 0.2μV/°C RTI (Typ: 0.15μV/°C) 
Gain drift: within 15ppm/°C (Typ: 7ppm/°C)
Noise: within 0.1μVp-p RTI (0.1 - 10 Hz)
Analog filterBessel low-pass filter (-12dB/oct.) selectable from 2, 4, 6, 8 Hz
A/D converterSpeed: 100 times/sec
Resolution: 16 bit
Min. display resolution1/10000
Secondary calibrationCalibration can be carried out without an actual load by connecting a resistor to one of the bridges of a loadcell.
SETTING SECTION
Setting method? Keyboard operation (membrane switch with a key click buzzer) 
? External setting is available by installing a setting point option or RS-232C option
Setting value storage? Initial set values: NOV RAM (Non-volatile RAM)
? Other set values: C-MOS RAM with backup of a lithium battery (Effective for more than 7 years depending on usage conditions and storage environment.)
Setting value protectionSetting operation can be locked to prevent unauthorized modifications of default values and calibration by malfunction
 
INPUT/OUTPUT SECTION
External output signalTransistor’s open collector output (Emitter = COM terminal); Output is LO when transistor is ON (Near zero, SP1, SP2, SP3, go or comp, over, under, high limit, Low limit, stable, weight alarm or error, run)
External input signalON when shorted to COM terminal by TTL-level relay, switch, transistor, or open collector output. (Feed / discharge, tare ON, tare OFF, zero, gross / net, hold or judgment, start, stop) (Drive current: 10mA or less)
Output Conditions- SP1: Net weight >= final weight-SP1
- SP2: Net weight >= final weight-before final
- SP3: Net weight >= final weight-FF
- Under: Net weight < final weight-underweight
- Over: Net weight > final weight-overweight
- Go: Final weight+overweight >= netweight >= final weight-underweight
Interface
  • ? SIF:

  • 2-wire type serial interface (standard); Interface to link with Unipulse printer or external display

  •  

  • ? SPI:

  • Interface for set-point units (Optional); Interface to enter various set values via digital switches

  •  

  • ? BCO:

  • BCD parallel data output interface (Optional): Parallel interface to transmit weight data to a printer, external display, PC or sequencer.

  •  

  • ? 232:

  • RS-232C communication interface (Optional): Write (change) / read weight data, various statuses and setting values from a PC or sequencer.

  •  

  • ? 485:

  • RS-485 communication interface (Optional): Allows longer-distance communication than RS-232C. ID numbers are set, and multiple units of F701 are parallel-connectable.

  •  

  • ? DAC:

  • D/A converter interface (Optional); Interface to convert weight data to current signal and output it.

 
DISPLAY SECTION
Display unitNumerical display (7 digits) with a character height of 18.5 mm by fluorescent display tube
Display value5 digits, Minus sign displayed on most significant digit
Scale capacity5-digit numerical values
Min. scale division1 to 100
Decimal pointSelectable from 0, 0.0, 0.00, 0.000 (with zero blanking function)
Over-scale displayInput of A/D converter overflow, Net weight over the set net value, scale capacity + 9 scale divisions, Gross weight over the set gross weight
Center zeroTrue zero point or the center of each value is displayed.
Unit displaySelectable from t, kg, g, N, lb, none
Status displaySP3, SP2, SP1, LOCK, ZT, ZALM, STAB, TARE, NET, GROSS, HI LIM, HI, GO, LO, LO LIM, HOLD, NZ
 
GENERAL SPECIFICATIONS
Power supply voltage85 - 110V, 102 - 132V, 170 - 220V, 187 - 242V AC (Please specify when ordering), 50/60 Hz
Power consumptionApprox. 15VA
Operating conditionsTemperature: Working temperature range -10°C - +40°C; Storage temperature range -20 - +85°C
Humidity: 85% RH or less (non-condensing)
External dimensions192 (W) x 96 (H) x 160 (D) [mm] (protruding parts not included)
Panel cutout dimensions186(+2 / -0) (W) x 92 (+1 / -0)(H) mm  (protruding parts not included)
*Installation panel thickness: 1.6 mm or more
WeightApprox. 2.2 kg
 
ACCESSORIES
AC input cord (2m)1
Spare fuse (1A)1
Loadcell input connector1
Control signal I/O connector1
Flathead screwdriver1
Operation Manual1
Set point unit connector (when set point unit option is installed)1
BCD output connector (when BCD output option is installed)1
D/A converter connector (when D/A converter option is installed)1
  
Drum Filling Machine

Option

ModelDescription
SPISet point unit interface
BCOBCD parallel data output interface
232RS-232C communication interface
485RS-485 communication interface
DACD/A converter interface
  
Drum Filling Machine

Optional accessories

ModelDescription
E780Set point unit
LB01-NHLithium battery (with NH connector)
CAAC2P-P2AC input cord 2 m
CAAC3P-CEE7/7-P1.5AC input cord (250V withstand voltage) 1.5 m
CN3P-2P3P-2P conversion plug for AC input cord
CA4131(6-core) cable with JR connector at one end (cable end is separated) 3 m
CA4230JR-PRC conversion relay (6-core) cable 0.3 m
CA4311JR-PRC conversion relay (6-core) 4-wire type / 6-wire type (for 520A) 1m
CA7Coaxial cable with BCN on both ends 1.5 m
CA8BNC-alligator clip cable 1.5 m
CA3150Flexible flat cable with 57F 36 pins at both ends
CN2157 series 36p connector for BCD output / set point unit
CN2357 series 24p connector for external input / output
CN35D-sub 25p connector for RS-232C

CONTACT US

Skype: fayfaywang1027

QQ: 429682794

Whatsapp: 008618016442021

E-mail: [email protected]

https://glzon.en.alibaba.com/

cel: +0086 18016442021

主站蜘蛛池模板: 午夜国产福利在线 | 国产福利在线观看你懂的 | 日韩欧美在线观看视频一区二区 | 在线免费观看a视频 | 国产成人免费高清激情视频 | 欧美成成人免费 | 一区二区三区日韩免费播放 | 欧美久久一区二区 | 一本色道久久综合亚洲精品加 | 久久久精品久久久久久久久久久 | 国产成人精品免费视 | 欧美毛片一级的免费的 | 精品视频一区二区三区在线观看 | 成人亚洲 | 最新在线精品国自拍视频 | 青草国产在线观看 | 狠狠大日本亚洲香蕉亚洲 | 欧美一区二区三区久久久 | 黄色一级日本 | 中文字幕乱码在线观看 | 狠狠色欧美亚洲狠狠色www | 成人免费黄色大片 | 在线中文字幕不卡 | 日本人伦一区二区三区 | 欧美偷窥自拍 | 欧美视频一区在线 | 国产手机在线国内精品 | aaaa级毛片 | 午夜视频在线观看网站 | 成人影片网址 | 国内精品区一区二区三 | 免费在线看黄网址 | 日本在线观看高清不卡免v 日本在线观看免费 | 黄色片网址大全 | 一级α一级α片免费观看网站 | 国产三级免费观看 | 精品视频免费在线 | 国产高清av在线播放 | 日韩在线视频一区二区三区 | 国产成+人+综合+亚洲不卡 | 国产日韩欧美综合 |